beautypg.com

FEC MICRO NR User Manual

Page 83

background image

FEC Micro Nutrunner Operations Manual

Chapter 7: System Operations (Rev. 2.1: 12/12)

Page 7-15

Data No.14 Speed Change Torque [Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0
Set the torque value that switches slow down speed to torque speed.





Data No.16 SNUG Torque [Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0
Snug Torque is the control start point when fastening to a Standard Angle.

Angle (of rotation) Judgment is conducted from Snug Torque to Fastening end when
this torque value is achieved. The Angle when this torque value is achieved is con-
sidered the 0° start point for judgment.

(Example) When [16: SNUG Torque] is 0.01Nm, [22: Standard Angle] is 90°.





















41:Freerun time

or 60:Freerun Revolutions

Time/Revolution

Speed

50:Initial Speed

40:Initial Time

53:Torque Speed

52:Slow Down Speed

51:Freerun Speed

14:Speed change torque

Even if [60: Freerun Revolutions] or [41: Freerun Time Limit] are not achieved, the
speed will change to Torque Speed when [14: Speed Change Torque is detected.

Torque

Angle

90°

Judgment torque

16 SNUG

0.01Nm

22 Standard Angle

All values related to Angles are referenced from [16: SNUG Torque]