Chapter 4: System Setup and Wiring
Page 4-14
4.6.1 MNR Unit DIP SW1 Settings
{ Switch 1 – START Signal Type .
P ON – Deadman (must hold START signal on for complete cycle)
P OFF – Pulse (200ms pulse required for start)
{ DIP Switch 2 – Snug Angle Count Method
P ON – Angle count starts at SNUG torque and continues whether SNUG torque remains
above or below once angle count starts
P OFF – (DEFAULT) Angle count starts at SNUG torque and only counts angle when
torque is at or above SNUG torque
SW1-2 ON
[In case Standard Angle is 90°]
90 °
SNUG TQ
SW1-2 OFF
[In case Standard Angle is 90 °]
50°
40 °
SNUG TQ
{ DIP Switch 3 – Display Mode
P ON - Special
P OFF - Standard
{ DIP Switch 4 – 7.
P Always OFF
{ DIP Switch 8. – Enable X-Y curve save to SD Memory
P OFF – Disabled
P ON - Enabled
***Additional setup required See 7.4.6.1
NOTE: The MNR unit must be powered off and on again after any DIP switch change.