Chapter 4: System Setup and Wiring

Page 4-14

4.6.1 MNR Unit DIP SW1 Settings

{ Switch 1START Signal Type .

P ON – Deadman (must hold START signal on for complete cycle)

P OFF – Pulse (200ms pulse required for start)

{ DIP Switch 2 – Snug Angle Count Method

P ON – Angle count starts at SNUG torque and continues whether SNUG torque remains

above or below once angle count starts

P OFF – (DEFAULT) Angle count starts at SNUG torque and only counts angle when

torque is at or above SNUG torque


SW1-2 ON

[In case Standard Angle is 90°]

90 °

SNUG TQ


SW1-2 OFF


[In case Standard Angle is 90 °]

50°

40 °

SNUG TQ


{ DIP Switch 3 – Display Mode

P ON - Special

P OFF - Standard

{ DIP Switch 4 – 7.

P Always OFF

{ DIP Switch 8. – Enable X-Y curve save to SD Memory

P OFF – Disabled

P ON - Enabled

***Additional setup required See 7.4.6.1

NOTE: The MNR unit must be powered off and on again after any DIP switch change.