Chapter 7: System Operations

Page 7-12



「D-NO」 「PARM」 「DATA」

0 1 Calibration Torque (CAL value)


0 1 Peak Low Torque Limit


0 1 Peak High Torque Limit






0 8 Rundown Revolution Low Limit


0 8 Rundown Revolution High Limit

Last data of PARAMETER 8





FIG. 7-2-4b Parameter display D-No selection




When Parameter Display mode is enabled, the [D-No] display will show 2 digits (10-69)
representing the preset data number. The [DATA] display will show the corresponding preset data
value and the parameter display [PARM] will indicate the parameter number (from 0 ~ 8). Use the
[

] and [

] keys to change the preset data number [D-NO]. If the [D-NO] display is showing the

number 69 of the parameter number 1, pressing the [

] key will change the [D-NO] display to the

number 10 of the parameter number 2.

You can verify the fastening parameters by pressing the [

] and [

] keys at any time.