(2)(3)
DC and AC Current
Range
Resolution
Accuracy
60.00 mA
10 µA
± (1 % + 5 digit)
600.0 mA
100 µA
6.000 A
1 mA
± (1.5 % + 5 digit)
10.00 A
10
mA
2. For 10 A terminal, > 6 A DC or AC rms for 10 seconds ON and 15 minutes
OFF.
3. For AC current ranges, frequency is verified for 20 Hz to 1 kHz.
Recorder Specifications
Scope Trend Plot
Display Mode
Full view, Normal
Record Length
800K points, > 24 hours
Number of
Channels
2
Multimeter Trend Plot
Display Mode
Full view, Normal
Record Length
1.2 M dots, > 24 hours
Number of Channels
1
Scope Recorder
Display Mode
Full view, Normal
Max. Record Length
Single Channel: 7M points
Dual Channel: 3.5 M points
Number of Channels
2
Maximum Record Size
to External Storage
4GB, 3000 hours