B&K Precision 2870 - Datasheet User Manual
Model 2870, Model 2860a, Specifications
For your nearest distributor, call 800-462-9832 or www.bkprecision.com
33
2870
2860A
■
Heavy Duty 1500 VDC rating
■
Ruggedized construction
■
Includes rubber boot
■
Withstands 5-foot drop
■
Extra large, high contrast LCD display
■
Gasket sealed against dirt and contaminants
■
Water resistant
■
High energy fused on all current ranges
■
Auto power off saves batteries
■
Built in probe holders
■
Non-slip grip
■
Extensive overload protection
Model 2870
■
0.25% DCV accuracy
■
True RMS
■
Autoranging
■
Analog bargraph
■
3 3/4 digit, 3200 count
■
Data hold, delay hold
Model 2860A
■
0.5% DCV accuracy
■
Manual ranging
■
3 1/2 digit, 2000 count
■
Large 0.8" LCD display
Five Year Warranty
DC Volts
Auto/Manual ranging
Manual ranging
Ranges
320mV, 3.2V, 32V, 320V, 1500V
200mV, 2V, 20V, 200V, 1500V
Resolution
100µV, 1mV, 10mV, 100mV, 1V
100µV, 1mV, 10mV, 100mV, 1V
Accuracy
±(0.25% rdg + 2 dgt)
±(0.5% rdg + 1 dgt)
Overload protection
1500V peak
1500V peak
Input Impedance
10M
Ω
10M
Ω
AC Volts
Auto/Manual ranging
Manual ranging
True RMS
avg. responding, rms reading
Ranges
3.2V, 32V, 320V, 750V
200mV, 2V, 20V, 200V, 1000V
Resolution
1mV, 10mV, 100mV, 1V
100µV, 1mV, 10mV, 100mV, 1V
Accuracy
±(1.3% rdg + 3 dgt)
±(1.25% rdg + 4 dgt)
Frequency Response
40Hz - 1kHz
40Hz - 500Hz
Overload Protection
1100V peak
1500V peak
Input Impedance
10M
Ω
10M
Ω
Current
Auto/Manual ranging
Manual ranging
AC True RMS
AC avg. responding, rms reading
Ranges
320µA, 3.2mA, 32mA, 300mA, 20A*
200µA, 2mA, 20mA, 200mA, 20A*
Resolution
0.1µA, 1µA, 10µA, 100µA, 10mA
0.1µA, 1µA, 10µA, 100µA, 10mA
Accuracy (DC)
±(1.0% rdg + 2 dgt),
±(1.0% rdg + 1 dgt),
±(2.0% rdg + 3 dgt) for 20A
±(2.0% rdg + 3 dgt) for 20A
Accuracy (AC)
±(2.5% rdg + 3 dgt)
±(1.5% rdg + 3 dgt),
±(2.5% rdg + 5dgt) for 20A
±(2.5% rdg + 4 dgt) for 20A
Frequency Response
40Hz - 1kHz
40Hz-500Hz
Overload Protection
High energy 600V, 1A full for µA/mA, High energy 600V, 15A for 20A
Resistance
Auto/Manual ranging
Manual ranging
Ranges
320
Ω
, 3.2k
Ω
, 32k
Ω
, 320k
Ω
, 200
Ω
, 2k
Ω
, 20k
Ω
, 200k
Ω
,
3.2M
Ω
, 32M
Ω
2M
Ω
, 20M
Ω
Resolution
0.1
Ω
, 1
Ω
, 10
Ω
, 100
Ω
, 1k
Ω
, 10k
Ω
0.1
Ω
, 1
Ω
, 10
Ω
, 100
Ω
, 1k
Ω
, 10k
Ω
Accuracy
±(0.5% rdg + 2 dgt)
±(0.75% rdg + 1 dgt)
±(2.0% rdg + 5 dgt) for 32M
Ω
±(1.5% rdg + 5 dgt) for 20M
Ω
Overload Protection
600V peak
600V peak
Diode Check
Tested at 1.5mA, 3.3V max typical tested at 1mA 3.2V max typical
Continuity
Beeper sounds below 200
Ω
approx.
Beeper sounds below 100
Ω
approx.
Display
0.53" LCD, 3200 count with
0.8" LCD, 1999 count
65-segment analog bargraph
Sampling rate
2/sec., 12/sec. for bargraph
2.5 /sec.
Operating Temperature
32° to 122°F (0°C to 50°C), <80% RH
Power
Single 9V battery
Battery life
200 hrs typ (alkaline)
250 hrs typ (alkaline)
Auto power off
Approx. 10 min.
Approx. 30 min.
DImensions (H x W x D)
6.88 x 3.19 x 1.25" (175 x 81 x 32mm)
6.88 x 3.5 x 1.5" (175 x 89 x 38mm)
Weight
18.3 oz. (519g)
12 oz. (353g)
Specifications
models
2870
2860A
SUPPLIED: Battery, test leads, rubber holster, manual
OPTIONAL: TL-1 Replacement Test Leads , TL-2A Deluxe Test Leads, TL-3 Accessory TIp Kit
(for TL-2A), TL-130A General Purpose DMM Kit, PR-28A High Voltage Probe,
CP-3 AC/DC Current Clamp Adapter
Carrying Case (not included): LC-29B
The “Survivor” name says it all!
*10 A continuous, 20A for 30 seconds max.
Accessories