B&K Precision 2709B - Datasheet User Manual
Auto ranging true rms tool kit, Rue rms, Model 2709b data sheet
w w w.bk prec ision.c om
Tel.: 714.921.9095
DC Current
Ranges
660 uA, 6600 uA, 66 mA, 400 mA, 10 A
Resolution
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA
Accuracy
660 uA to 400 mA ranges: ±(1.5 % rdg + 2 dgts)
10 A range: ±(3.0 % rdg + 3 dgts)
Input Protection
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses
10A Input
10 A for 60 sec max. followed by a 10 minute cooling period
AC Cu rrent (Tru e R MS) (50 Hz -500 Hz )
Ranges
660 uA, 6600 uA, 66 mA, 400 mA, 10 A
Resolution
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA
Accuracy
660 uA to 400 mA ranges: ±(2.0 % rdg + 10 dgts)
10 A range: ±(3.5 % rdg + 10 dgts)
Crest Factor
≤ 3
Input Protection
0.5 A/500 V & 10 A/600 V fast blow ceramic fuses
10A Input
10 A for 60 sec max. followed by a 10 minute cooling period
Resis tan ce
Ranges
660 Ω, 6.6 kΩ, 66 kΩ, 660 kΩ, 6.6 MΩ, 66 MΩ
Resolution
0.1 Ω, 1.0 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ
Accuracy
660 Ω to 660 kΩ ranges: ±(1.2 % rdg + 5 dgts)
6.6 MΩ range: ±(2.0 % rdg + 5 dgts)
66 MΩ range: ±(3.5 % rdg + 5 dgts)
Open Circuit Voltage (typical) -0.45 VDC (-1.2 VDC on 660 Ω range)
Overload Protection
500 VDC/ACrms
Capacitance
Ranges
6.6 nF , 66 nF, 660 nF, 6.6 uF, 66 uF, 660 uF, 6.6 mF, 66 mF
Resolution
1 pF, 10 pF, 100 pF, 1 nF, 10 nF, 100 nF, 1 uF, 10 uF
Accuracy
6.6 nF range: ±(3.0 % rdg + 30 dgts)
66 nF to 660 uF ranges: ±(3.0 % rdg + 5 dgts)
6.6 mF to 66 mF ranges: ±(5.0 % rdg + 20 dgts)
Overload Protection
500 VDC/ACrms
Fre qu ency
Ranges
660 Hz, 6.6 kHz, 66 kHz, 660 kHz, 6.6 MHz, 66 MHz
Resolution
0.1 Hz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz
Accuracy
±(0.1 % rdg + 3 dgts)
Sensitivity
10 Hz to 6.6 MHz: >2.5 Vrms, 6.6 MHz to 66 MHz:
>2.5 Vrms <5 Vrms
Minimum Pulse Width
>25 ns
Duty Cycle Limits
>30 % and <70 %
Overload Protection
500 VDC/AC rms
Diode Te st
Test Current
1.2 mA (typical)
Resolution
1 mV
Accuracy
±(3.0 % rdg + 3 dgts)
Audible Indication
<0.03 V
Open Circuit Voltage
3.5 VDC (typical)
Overload Protection
500 VDC/ACrms
Con tinuity
Audible Indication
Less than 30 Ω
Response Time
100 ms
Overload Protection
500 VDC/ACrms
General
Display
3 3/4 digit, 6600 count LCD
Polarity
Automatic, positive implied, negative polarity indication
Overrange
OL or -OL is displayed
Low Battery Indication
Battery symbol will display when battery voltage drops below
operating levels
Measurement Rate
2 times per second
Auto Power Off
Approximately 30 minutes
Operating Environment
0ºC to 50ºC at <70 % relative humidity
Storage Environment
-20ºC to 60ºC at 0 to 80 % relative humidity
Accuracies
Stated accuracy at 23ºC +5ºC at <75 % relative humidity
Temperature Coefficient
0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC)
Power
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life
150 hours typical
Dimensions
165 mm (H) x 78 mm (W) x 42.5 mm (D)
Weight
Approximately 10 oz. (285 g) with battery and hanger
Auto Ranging True RMS Tool Kit
®
DMM
Model 2709B
Data Sheet
Technical data subject to change
© B&K Precision Corp. 2013
Page 1 of 2
The 2709B is a full featured auto ranging true RMS DMM that combines
performance, value and functionality. The 6600 count LCD has a green back light
that allows the meter to be used in dimly lit environments. The 2709B can
measure resistance values up to 66 MΩ and capacitance to 66 mF. With the auto
power off feature you won’t have to worry about accidental battery consumption.
Value-packed features make this meter a must in every "Tool Kit
®
".
Features
■
Magnetic hanger
■
One-handed operation
■
True RMS
■
Large easy-to-read LCD with backlight
■
Auto/manual ranging
■
Auto power off
■
DC voltage to 1000 V
■
Measures up to 10 A (AC & DC)
■
AC voltage to 750 V
■
Resistance to 66 MΩ
■
Capacitance to 66 mF
■
Frequency counter to 66 MHz
■
Diode test
■
Continuity test
D C Volts
Ranges
660 mV, 6.6 V, 66 V, 660 V, 1000 V
Resolution
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy
±(0.5 % rdg + 2 dgts)
Input Impedance
660 mV: >100 MΩ; 6.6 V: 10 MΩ; 66 V to 1000 V: 9.1 MΩ
Overload Protection
1000 VDC or 750 VACrms
A C Volts (T rue RM S) (50 Hz -500 Hz )
Ranges
660 mv, 6.6 V, 66 V, 660 V, 750 V
Resolution
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy
660 mV range at 50 Hz to 60 Hz ±(1.5 % rdg + 8 dgts)
6.6 V to 660 V ranges: ±(1.5 % rdg + 8 dgts)
750 V range: ±(2.0 % rdg + 8 dgts)
Crest Factor
≤ 3
Input Impedance
660 mV: >100 MΩ; 6.6 V: 10 MΩ; 66 V to 750 V: 9.1 MΩ
Overload Protection
1000 VDC or 750 VACrms
Specifications
2709B
model
Supplied Accessories: User manual, one set of test leads, one spare fuse, and 9V battery (installed)
Three-Year Warranty
RUE RMS
T
Select between Auto or
Manual ranging
A ut o/ Manual Ranging