ZyXEL Communications ZyXEL ZyWALL 2WG User Manual
Page 598
Chapter 42 Firmware and Configuration File Maintenance
ZyWALL 2WG User’s Guide
598
Figure 390 Menu 24.7.2 As Seen Using the Console Port
2 After the "Starting Xmodem upload" message appears, activate the Xmodem protocol on
your computer. Follow the procedure as shown previously for the HyperTerminal
program. The procedure for other serial communications programs should be similar.
3 Enter “atgo” to restart the ZyWALL.
42.5.11 Example Xmodem Configuration Upload Using HyperTerminal
Click Transfer, then Send File to display the following screen.
Figure 391 Example Xmodem Upload
After the configuration upload process has completed, restart the ZyWALL by entering
“atgo”.
Menu 24.7.2 - System Maintenance - Upload System Configuration File
To upload system configuration file:
1. Enter "y" at the prompt below to go into debug mode.
2. Enter "atlc" after "Enter Debug Mode" message.
3. Wait for "Starting XMODEM upload" message before activating
Xmodem upload on your terminal.
4. After successful firmware upload, enter "atgo" to restart
the system.
Warning:
1. Proceeding with the upload will erase the current
configuration file.
2. The system's console port speed (Menu 24.2.2) may change when it is
restarted; please adjust your terminal's speed accordingly. The password
may change (menu 23), also.
3. When uploading the DEFAULT configuration file, the console
port speed will be reset to 9600 bps and the password to "1234".
Do You Wish To Proceed:(Y/N)