Inserting, Appending and Editing Filters

To edit an existing filter, add a new filter in a specific location in the filter
table or append a filter to the bottom of the table, follow these steps:

1. Use the Toggle command (option T) to select input or output filters.

Next, choose one of the following and proceed to step 2:
A. To edit an existing filter, type E to select Edit a filter of the chosen
type.
B. To insert a new filter, type I to select Insert a new or buffered filter of
the chosen type.
C. To append a new filter at the bottom, type A to select Append a new
or buffered filter of the chosen type.

2. Follow the IAD messages to enter values for the following parameters:

3. When you enter the last parameter, the IAD displays the summary

information and saves the configuration. The IAD displays the IP Filter
Configuration menu.

4. Continue with other configuration tasks, or press Escape to return to

the Router Configuration menu.

5. Reset the IAD (page

14

) when you finish IP filter configuration.

NOTE

At any time during the creation or editing of a filter, you can
press Escape to abort the process. The IAD displays the IP
Filter Configuration menu and the filter table is unchanged.

Table 5–1.

Filter Parameters

Parameter

Description

Filter state

Idle | Active

Filter action

Pass | Discard

Filter protocol

IP | ICMP | IGMP | TCP
| UDP

Filter Source IP Low Address

IP address

Filter Source IP High Address

IP address

Filter Source Port Low

Port number

Filter Source Port High

Port number

Filter Destination IP Low Address

IP address

Filter Destination IP High Address

IP Address

Filter Destination Port Low

Port number

Filter Destination Port High

Port number