Appendix B: Metering

58

Siemens Energy & Automation, Inc.

B Metering

B.1 Accuracy

Table B.1 Metering Accuracies

Parameter

Range

Accuracy

rms Current (L & G)

0-250% I

n

Displayed in Amperes

±1% of measurement from 50-125% of I

n

±0.5% of I

n

from 10- 50% of I

n

Average rms Current

0-250% I

n

Displayed in Amperes

±1% of measurement from 50-125% of I

n

±0.5% of I

n

from 10-50% of I

n

Ampere Demand per Phase

0.. 250% I

n

Displayed in Amperes

±1% of measurement from 50-125% of I

n

±0.5% of I

n

from 10-50% of I

n

Average Ampere Demand

0-250% I

n

Displayed in Amperes

±1% of measurement from 50-125% of I

n

±0.5% of I

n

from 10-50% of I

n

rmsVoltage (L-L and L-N)

10-125% V

n

Displayed in kV

±1% of measurement from 50-125% of V

n

±0.5% of V

n

from 10-50% of V

n

Average rms Voltage

10-125% V

n

Displayed in kV

±1% of measurement from 50-125% of V

n

±0.5% of V

n

from 10-50% of V

n

Active Power (kW)

0-999,999.99 kW

±2% of measurement from 50-125% of P

n

±0.1% of V

n

from 10-50% of P

n

1, 5

kW Demand

0-999,999.99 kWD

±2% of measurement from 50-125% of P

n

±0.1% of V

n

from 10-50% of P

n

1, 5

kW Hours

0-999,999.99 kWHR

±2% of measurement from 50-125% of P

n

±0.1% of V

n

from 10-50% of P

n

1, 3, 5

Apparent Power (kVA)

0-999,999.99 kVA

±2% of measurement from 50-125% of P

n

±0.1% of V

n

from 10-50% of P

n

1, 5

Volt-Amperes Reactive (kVAR)

0-999,999.99 kVAR

±2% of measurement from 50-125% of P

n

±0.1% of V

n

from 10-50% of P

n

1, 2, 5

kVAR Hours

0-999,999.99 kVARH

±2% of measurement from 50-125% of P

n

±0.1% of V

n

from 10-50% of P

n

1, 2, 3, 5

Power Factor

-1- 0-+1

±0.04

4

Frequency

45-65 Hz

±0.1% of reading providing voltage is 50% VT primary rating

1

Measured at PF=1. For |PF|<1, ±2% + angle error (±2% for |PF|

0.7)

2

Measured at PF=0. For |PF|>0, ±2% + angle error (±2% for |PF|

0.7)

3

Energy is accumulated in either kHR or MHR, selectable (parameter).

4

For power factor, 1 is considered “perfect,” negative is leading and positive is lagging.

5

P

n

= V

n

x I

n

, where V

n

= VT rating (120 V) and I

n

= CT rating (5A).

Note for all values: Stated accuracy applies only when the device is not in pickup. These measurements are valid over a frequency range of

45- 65Hz and include fundamental, second harmonic, and all odd harmonics up to the 13th harmonic of the fundamental line frequency.