beautypg.com

2 operation after baseboard replacement, 3 rebuild operation by automatic recovery of hdd, 4 notes on use of domain controller function – FUJITSU Primergy RX200 S2 User Manual

Page 289

background image

289

PRIMERGY RX200 S2 User’s Guide

9

O

p

eration

a

nd
Mainten

ance

9.10.2 Operation after Baseboard Replacement

If the baseboard is replaced due to an error when the on-board SCSI array controller function is used for

this server, the logical drive of the array controller is initialized again after replacement. This is because

the data integrity information showing whether data was written correctly in the past is stored in the

baseboard. As the information is lost due to replacement, the initialization is automatically executed to

ensure the data integrity. This does not mean hard disk failure.

For behavior of the initialization, see "Onboard SCSI RAID User’s Guide 1.4 Rebuilding/Initializing a

Logical Drive".

9.10.3 Rebuild Operation by Automatic Recovery of HDD

When the on-board SCSI array controller function is used for this server, if the retry count against

recoverable hard disk error exceeds the threshold, automatic rebuild function runs to check the entire

disk. While the automatic rebuild function is running, the hard disk failure lamp blinks, and the front

maintenance lamp comes on due to the ServerView function.

A log "A manual rebuild has started on logical drive." remains in Log Information Viewer on GAM.

During automatic rebuild, hard disks can be accessed, but the access performance is affected. The

performance may be lowered up to 54%. After automatic rebuild is completed, the hard disk can be used

in the redundant state. But, the hard disk should be replaced as soon as possible.

If the above symptom (lamp, message on GAM) occurs although hard disk is not replaced, please

contact the maintenance person or system administrator.

* For automatic rebuild events, ServerView notification are not executed. However, if automatic rebuild

fails, ServerView notification is done as hard disk failure.

9.10.4 Notes on Use of Domain Controller Function

In the case of disk array configuration with the on-board SCSI array controller in this server, if it is used

as a domain controller for Windows Server 2003 x64 Editions, Windows Server 2003, or Windows 2000

Server, the following warning message may be logged in the OS event log during startup.

For this server, the writing cache is always disabled, and never becomes enabled for the RAID logical

drive configured with SCSI array controllers. However, this message indicates that the logical drive

cache configuration is not correctly recognized. Even if this message is logged, the system operation is

not affected, and data is not damaged.

Type: Warning

Source: Disk

Description: The driver detects a valid writing cache of

\Device\Harddisk0\DR0. The data may be damaged.