9.10Maintenance & Notes

This section explains the details of the maintenance & Notes.

9.10.1 Hard disk failure is detected

If hard disk failure is detected during POST, the RX200 S2 on-board SCSI array controller stops with

the following message.

If the controller stops with this message, insert the floppy disk "OnBoard RAID Utility" into the floppy

disk drive of the system, and press the [Ctrl] key and [A] key at once to start up the system from the

floppy disk. The utility automatically starts up. The following message appears on the utility.

As shown here, if the message "Fatal Error happened. Please call support engineer." appears, do not

start up the system. Please contact the maintenance person and system administrator.

Warning!: The array is degraded. Press [Ctrl] [A] to continue after

insert Floppy Disk.

Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 0
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
curState: 1 prvState: 0

Previous Physical Disk States:
ID0 : Failed ID1 : Failed

Current Physical Disk States:
ID0 : Online ID1: Failed

Fatal ERROR happened. Please call support engineer

Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 0
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
curState: 1 prvState: 3

Previous Physical Disk States:
ID0 : Online ID1 : Failed

Current Physical Disk States:
ID0 : Online ID1: Failed

OK. You can boot system.
Please check HDD status after boot