Chapter 8 Hardware Configuration/Utilities

8.3.7 RAID Properties Submenu

Sets an array configured with the onboard SCSI array controller.

table: Items on the RAID Properties Submenu

Item

Setting

Contents

Array Disk?

• Yes (array type/Linux array

type)

• No (other types than array

type/Linux array type)

Sets whether or not the hard disk unit configures a
disk array.

Hot Spare

No (Fixed parameter)

The server does not support this.

Status

-

Displays the hard disk status when a disk array is
configured.

• [Primary] or [OK]

Indicates that the hard disk unit is operating
normally.

• Failed

Indicates that the hard disk unit has failed.

• Out of Sync

Indicates that the hard disk unit being rebuilt.

• Missing

Indicates that the hard disk unit is not installed or
recognized.

Size (MB)

-

Indicates the hard disk capacity.

LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IMx.xx.xx

Esc=Abort/Exit ArrowKeys=Select Item -/+=Change[Item]
Home/End=Select Item Enter=Execute

SCSI
ID
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Array
DISK?
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]
[No]

RAID Properties Array: SCSI ID: Size(MB):

Hot
Spare
[No]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]
[-]

Status

Predict
Failure

Size
(MB)

Device Identifier

-

1020/1030
SDR CEM318

***MB