■ Notes on Installation

Drivers

For expansion card drivers, refer to "2.3.5 Expansion Cards Supported by ServerStart" ( pg.48).

Notes on Each Card

For notes of specific expansion cards, refer to the manuals supplied with the card and the notes provided

with the server. Also, check the following for respective expansion cards.

SCSI Card/RAID Card

• Connection of a SCSI device

• For optional device connection using a SCSI or RAID card, refer to "7.10 Connection of Optional

Devices" ( pg.201).

• Connect a SCSI device supported by this server to the SCSI or RAID card.

Operations of unsupported SCSI devices are not guaranteed.

BIOS Settings

The expansion ROM for expansion cards is disabled on this server. To configure an expansion card, the

expansion ROM must be temporarily enabled in the BIOS Setup Utility. The configuration procedures

are as follows.

1

Enable the expansion ROM of the slot for the expansion card to be configured.

Start up the BIOS Setup Utility and select the "

PCI SLOTS Configuration Submenu"

( pg.218) from the [Advanced] menu. Change [Option ROM Scan] from [Disabled] to

[Enabled].

2

From the "8.2.17 Exit Menu" ( pg.232), select [Save Changes & Exit] to exit

the BIOS Setup Utility.

3

Restart the server and configure the expansion card in POST.

4

After configuring the expansion card, start up the BIOS Setup Utility again and

return the setting you have changed in Step 1 to the original setting.