beautypg.com

11 server menu – FUJITSU Primergy RX200 S2 User Manual

Page 224

background image

224

Chapter 8 Hardware Configuration/Utilities

8.2.11 Server Menu

Configures the server settings.

table: Items on the Server Menu

Item

Setting

Description

O/S Boot Timeout

• Disabled (at the time of

purchase)

• Enabled

Sets whether to enable or disable the OS Boot
Monitoring function, when ServerView is installed to
the OS.
If for some reason booting the operating system is
interrupted when this function is enabled, the system
will automatically restart.
The OS Boot Monitoring function can also be
enabled or disabled from ServerView.

Note:

If ServerView is not installed to the OS, be

sure to set to [Disabled].

If the setting is enabled, the server may

automatically turn off or restart unexpectedly.

Even when ServerView is installed on the OS,

if starting the system while the Server

Management Tools disk is inserted, be sure to

disable the OS Boot Monitoring function.

If the system is started with this function

enabled, the server may automatically turn off

or restart improperly.

If the OS Boot Monitoring function is needed,

it should be reset to enabled before resuming

normal server operation.

When setting this function, refer to

"ServerView User's Guide" to fully learn about

its specifications, in order to use it properly

with the correct settings.

Item Specific Help

PhoenixBIOS Setup Utility

Main

Advanced

Security

Server

Exit

Select Sub-Menu

F1

Esc

Select Item

Select Menu

Change Values

-/+

Enter

Info

Exit

F9

F10

Setup Defaults

Save and Exit

O/S Boot Timeout: [Disabled]
Mode [Continue]
Timeout value [0]
ASR&R Boot Delay(min): [2]
Power Cycle Delay: [5]
Boot Retry Counter: [3]
Diagnostic System: [Disabled]
Critical Temperature Monitoring:[Disabled]

Clear Screen Delay(sec): [5]

IPMI

CPU Status
Memory Status

Console Redirection

Memory scrub: [Enabled]
BIOS runtime logging: [Enabled]

LAN Setting