BaseStation 3200 Advanced Irrigation Controller Manual

To set up the water source

1. Turn the dial to the Water Sources position.

2. Press the Next button to highlight the Water Sources (POCs) Setup option.

3. Press the Enter button. The Setup POCs

screen displays.

4. In the Water Source field, press the + button

to select the POC that you want to set up.

5. Press the Next button to move to the POC

Priority field, and then press the + or

button to set the priority as High, Medium,

Low, or Off. The system will use the high

priority water source first, and then switch to

medium, and finally to low.

Note: When you have multiple POCs on a mainline, the priority setting allows you to use the

POC with the lowest cost of water first (high priority), but you can only set priorities when you

have a normally closed master valve installed on the POCs. Use the Off setting for POCs that

do not have flow meters or master valves.

6. Press the Next button to move to the Design Flow GPM field, and then press the + or –

button to enter the amount of flow in gallons per minute (GPM) that is allowed through this

point of connection for the irrigation system.

7. Press the Next button to move to the High Flow Limit GPM field, and then press the + or

button to enter the maximum amount of flow in gallons per minute.

8. Press the Next button to move to the Shut Down field. If you want programs using this POC

to be stopped and corresponding MVs shut off when the flow rate exceeds the limit, press the

+ button to enter a Y (yes) in the field. If you do not want excessive flow to shut down the

system, enter an N (no) in the field.

9. Press the Next button to move to the Unscheduled Flow Limit GPM field, and then press the

+ or button to enter the maximum amount of unscheduled flow in gallons per minute.

10. Press the Next button to move to the Shut Down field. If you want the associated MVs to turn

off when an unscheduled flow exceeds this limit, press the + button to enter a Y (yes) in the

field. If you do not want excessive flow to shut down the system, enter an N (no) in the field.

11. Press the Next button to move to the Monthly Budget Gal field, and then press the + or

button to enter the maximum amount of water that can be used per month in gallons.

12. Press the Next button to move to the Shut Down field. If you want the associated MVs to turn

off when the amount of water used exceeds this limit, press the + button to enter a Y (yes) in

the field. If you do not want excessive water use to shut down the system, enter an N (no) in

the field.

13. Press the Next button to move to the Water Rationing field. To enable water rationing, press

the + button to display Enabled in the field. When you enable water rationing, the system

determines the daily water ration by dividing the number of gallons in the Monthly Budget

field by the number of days in the month. The system will use only the ration amount for daily

watering. If a day is skipped, that water ration is available the next day.