BaseStation 3200 Advanced Irrigation Controller Manual

11 – Troubleshooting

The BaseStation 3200 has built-in features for testing zones, valves, biCoders and biSensors. These

tests help you isolate and identify components and devices that are not working properly so you

know what needs to be repaired.

Testing a Specific Two-wire Device

When you test a two-wire device, the controller verifies the communication between the controller

and the device. The controller activates the device and measures the current and voltage. It

deactivates the device, and measures the voltage drop between the controller and the device.

1. Turn the dial to the Self Test position.

2. Press the Next or Previous button to select Test Single Two-wire Device, and then press the

Enter button.

3. In the Device to Test column, press the + or button to select the serial number of the device

that you want to test.

4. Press the Enter button to test the device.

The device will activate for less than a second

to measure the voltage and current through

the device. This test will return information

related to the type of device that was tested.

5. When you have finished viewing the test

results, turn the dial to the RUN position.

Possible Statuses for Valve biCoders

Refer to the following table for possible self-test statuses along with causes and suggestions for

resolving the issues.

Self-test

Status

Cause/Action

Open circuit

Wire connection between the valve biCoder and the valve solenoid is

broken – repair wire connections.

Valve solenoid is broken – replace solenoid.