beautypg.com

Baseline Systems BaseStation 3200 V12 User Manual

Page 114

background image

BaseStation 3200 Advanced Irrigation Controller Manual

4. Assign the primary zone to a program by giving the zone a water time. Make sure the water

time is sufficient to get through the longest day interval during the hottest time of the year

(typically ¾” water). Refer to Configuring Zone Settings on page 31.

5. Link the other zones in the area that is monitored by the sensor to the primary zone. Refer to

Linking Zones on page 42.

6. Set up a Day & Time start condition for the program. Refer to Setting Up Programs on page

46.

a. Start on desired days.

b. Start at desired time.

The controller will run every time it is programmed.

7. Set the Upper Limit watering strategy for the primary zone. Refer to the topic on configuring

your biSensors and setting up watering strategies on page 55.

a. Set the Upper Limit at field capacity.

8. Set up the Soak Cycles for the program. Refer to Using Soak Cycles on page 44.

a. Set up at least 3 cycles.