Adjusting the valve power level for a bicoder – Baseline Systems BaseStation 3200 V12 User Manual
Page 39

BaseStation 3200 Advanced Irrigation Controller Manual
To remove the zone from the current program, press the Previous button to return to
the Water Time field, and then press the – button to remove the watering time in the
field.
To assign the zone to a different program, perform the previous task to remove the
zone from the current program. Move to the Program field, and press the + or – button
to change the number to the new program that you want the zone to be assigned to.
To assign the zone to an additional program, move to the Program field, and press the +
or – button to change the number to the additional program that you want the zone to
be assigned to. Repeat steps 3 – 7 to configure the zone settings in the new program.
Note: The lower-left corner of the screen shows what programs the zone is assigned to.
10. After you have configured the settings for the current zone, perform one of the following
actions:
To configure another zone, press the Enter button until the number of the zone that you
want to configure displays in the Zone field at the top of the screen. Repeat steps 3 – 9.
When you have finished making changes, turn the dial to the RUN position.
Adjusting the Valve Power Level for a biCoder
If your irrigation system uses solenoids that have different power requirements, you can adjust the
valve power level of the biCoders that are attached to the zones associated with these solenoids.
Typically, you will perform this task under the guidance of Baseline Support.
Note: You only need to perform this procedure when the current read by the biCoder is less
than .110 Amps.
1. Turn the dial to the Advanced position.
2. Press the Next or Previous button to move to the Valve Power Setup option, and then press
the Enter button.
3. Press the + or – button to select the zone and biCoder that you want to adjust.
4. Press the Next button to move to the Valve Drive Power field, and then press the + or –
button to change the value.
You can adjust the valve power for any biCoder from a minimum of 1 to a maximum of 3. If a
biCoder does not support this feature, the word “Fixed” displays in the Valve Drive Power
field.
5. When you have finished making changes, turn the dial to the RUN position.
Page 33