BaseStation 3200 Advanced Irrigation Controller Manual
Searching For Start, Stop, & Pause Devices
Programs can be started, stopped, or paused by the following conditions monitored by a dedicated
device:
•
Whether the contacts on event biCoders are open or closed
•
Whether moisture levels are above or below a specified percentage as monitored by a
biSensor
•
Whether temperature values are above or below a specified level as monitored by either
moisture sensors or temperature sensors
Searching For and Assigning Event biCoders
The BaseStation 3200 supports 8 event biCoders.
1. Turn the dial to the Start, Stop, Pause position.
2. Press the Next or Previous button to highlight the Event Switches Setup option.
3. Press the Enter button. The Event Switches
screen displays.
4. All is highlighted in the Program column.
Perform one of the following:
To associate the event biCoder with the
full controller, continue to step 5.
To associate the event biCoder with a
specific program, press the + button to
move to that program number.
Continue to step 5.
5. Press the Next button to highlight Search.
6. Press the Enter button to search for event biCoders. The serial numbers of the biCoders are
shown in the Event Decoders column.
7. Press the + or – button to highlight the serial number of the event biCoder that you want to
assign.
8. Continue to the procedure for setting up the start, stop, and pause conditions for event
biCoders on page 59.
Page 34