beautypg.com

Baseline Systems BaseStation 3200 V12 User Manual

Page 61

background image

BaseStation 3200 Advanced Irrigation Controller Manual

Upper Limit – Allows watering at each start time, but the water time is adjusted to replenish

the moisture to field capacity. The user sets and manages the limit and the base water time.

Ensure that ½ inch or more of water is applied frequently enough to water sufficiently during

the hottest period of the season.

Make sure that you have soak cycles properly set up for the zones that will be using soil

moisture based watering. In addition to allowing the applied water to soak into the soil,

soak cycles allow time for the water to reach the biSensor depth so the soil moisture

readings are accurate. Refer to Using Soak Cycles on page 44.

Prerequisites for Watering with Soil Moisture Sensors

Your biSensors are installed and assigned in the BaseStation 3200. Make sure to assign the

correct biSensor to its primary zone. Making an incorrect assignment here will result in

unexpected and confusing water behavior. Refer to Searching For and Assigning biSensors on

page 36.

You have created scheduling groups (a primary zone with linked zones) that combine areas

with similar watering needs (hydrozones). For example, the zones that water the softball field

would be in one scheduling group and the zones that water the north lawn between the

sidewalk and the building would be in another scheduling group. Refer to Linking Zones

(Creating a Scheduling Group) on page 42.

To configure your biSensors and set up watering strategies

1. Turn the dial to the Smart Watering position.

2. Press the Next button to select Moisture

Sensor Setup, and then press the Enter

button. The Sensor Setup screen displays.

3. If you have more than one biSensor installed

and assigned to a primary zone, verify that the

correct primary zone displays in the Sensor

Primary Zone field (the serial number of the

assigned biSensor displays in the lower-left

corner of the screen). If the biSensor that you

want to configure is not displayed in the field,

press the + or button to select the correct one.

4. Press the Next button to move to the Water Strategy field, and then press the + or button

to select the water strategy that you want to use.

IMPORTANT NOTE! If you select the Upper or Lower Limit strategies, be sure to read the

information below for a complete explanation of these strategies.

5. Press the Next button to move to the Upper/Lower Limit field (the field that displays

depends on the water strategy that you selected). Press the + or button to change the

number in the field.

6. Press the Next button to move to the Limit Adjustment field.

Note: This field is typically used to offset the limit set by a calibration cycle. If you think that

you might need to use this field, contact Baseline Support for help.

Page 55