IDEC MicroSmart User Manual
Page 287
![background image](/manuals/350368/287/background.png)
17: U
SER
C
OMMUNICATION
I
NSTRUCTIONS
« FC4A M
ICRO
S
MART
U
SER
’
S
M
ANUAL
»
17-9
Transmit Digits (Bytes)
After conversion, the transmit data is taken out in specified digits. Possible digits depend on the selected conversion type.
Example: D10 stores 010Ch (268)
(1) Binary to ASCII conversion, Transmit digits = 2
(2) BCD to ASCII conversion, Transmit digits = 3
(3) No conversion, Transmit digits = 1
Repeat Cycles
When a data register is designated to repeat, consecutive data registers, as many as the repeat cycles, are used for transmit
data in the same conversion type and transmit digits.
Example:
Data of data registers starting with D10 is converted in BCD to ASCII and is transmitted according to the designated repeat
cycles.
010Ch
D10
Binar y to ASCII conversion
“0”
(30h)
“1”
(31h)
“0”
(30h)
“C”
(43h)
Transmitted data
“0”
(30h)
“C”
(43h)
Lowest 2 digits
ASCII data
010Ch
D10
Decimal
“0”
(30h)
“0”
(30h)
“2”
(32h)
“6”
(36h)
“8”
(38h)
Lowest 3 digits
“2”
(32h)
“6”
(36h)
“8”
(38h)
BCD to ASCII
00268
value
conversion
Transmitted data
ASCII data
010Ch
D10
No conversion
SOH
(01h)
FF
(0Ch)
FF
(0Ch)
Lowest 1 digit
ASCII data
Transmitted data
000Ch
D10
0022h
D11
0038h
D12
Data register No.: D10
Transmit digits:
2
Conversion type:
BCD to ASCII
000Ch
D10
“1”
(31h)
“2”
(32h)
“3”
(33h)
“4”
(34h)
00012
Repeat 1
0022h
D11
Decimal value
00034
BCD to ASCII conversion
Repeat 2
ASCII data
(1) Repeat cycles = 2
000Ch
D10
“1”
(31h)
“2”
(32h)
“3”
(33h)
“4”
(34h)
00012
Repeat 1
0022h
D11
Decimal value
00034
BCD to ASCII conversion
Repeat 2
0038h
D12
00056
Repeat 3
“5”
(35h)
“6”
(36h)
ASCII data
(2) Repeat cycles = 3