IDEC MicroSmart User Manual
Page 19
![background image](/manuals/350368/19/background.png)
1: G
ENERAL
I
NFORMATION
« FC4A M
ICRO
S
MART
U
SER
’
S
M
ANUAL
»
1-7
Operator Interface Communication System
The
MicroSmart
can communicate with IDEC’s HG series operator interfaces through RS232C port 1 and port 2.
Optional cables are available for connection between the
MicroSmart
and HG series operator interfaces. When installing
an optional RS232C communication adapter on the all-in-one type CPU module or an optional RS232C communication
module on the slim type CPU module, two operator interfaces can be connected to one
MicroSmart
CPU module.
For details about communication settings, see the user’s manual for the operator interface.
Applicable Cables to Operator Interfaces
Operator Interface
O/I Communication Cable
For Use on MicroSmart
HG1B, HG2A Series
FC4A-KC1C
RS232C por t 1 and por t 2
HG9Z-XC183
Por t 2 only
HG2F, HG3F, HG4F Series
FC4A-KC2C
RS232C por t 1 and por t 2
HG9Z-3C125
Por t 2 only
HG series Operator Interface
To RS232C Por t 1 or 2
O/I Communication Cable