Task 8: Configure the Interface (Serial Interface Users
Only)

The following table shows the settings available for the plotter’s serial interface
parameters, the factory defaults and the most likely requirements for different
computers.

Serial (RS-232-C) Settings

Likely requirement for ...

Available

Likely requirement for ...

Parameter

Available
settings

PC

Macintosh

Unix

Baud rate

1200

2400

4800

9600

19200

38400

9600

(2)

9600

Parity

(1)

None

Even

Odd

None

(2)

None

Italics = factory default

(1)

Parity of None = 8 data bits, 1 stop bit
Parity of Even or Odd = 7 data bits, 1 stop bit

(2)

Consult your software documentation.

The settings on the plotter must match those of the computer and software sending
the data. Use their documentation to find the requirements. If in doubt, try with
the above suggestions. If the plotter’s defaults already match the requirements,
then you can skip the rest of this task.