Recalibrating the plotter for accuracy – HP 700 User Manual
Page 153
Full menu mode
Utilities
Service config
7-5
Company confidential. Murillo/Ravillo User’s Guide. Final Freeze Status: Frozen
This is the cyan on page 7-5 (seq: 151)
This is the black on page 7-5 (seq: 151)
Recalibrating the Plotter for Accuracy
When to Recalibrate the Plotter
Your plotter was calibrated at the factory using HP Matte Film, with a thickness of
0.12 mm (0.0048 in);
at 23
_C (73_F),
with 50-60% relative humidity.
It will operate with greatest accuracy in similar environmental conditions. If you
are operating under significantly different conditions, you should recalibrate the
plotter as explained here. The plotter’s environmental specifications are given on
page 11-4. Also, if you are using a non-standard media type, you should first
recalibrate the plotter for that media type. For supported media types, see
page 3-3. You may also need to recalibrate the plotter if you have banding
problems, see page 9-20.
A Quick Guide to Whether Recalibration is Necessary
1
Make sure E/A0-size or D/A1-size media is loaded.
2
Print the
Service Configuration
plot, by choosing the option shown in the menu
graphic on the left.
3
Near the top of this plot are a pair of Xs. With a ruler measure the distance
between them. It should be 500 mm. If significantly different you will need to
recalibrate the plotter as described on the following page
X
X
500mm
Reconfiguring Your Plotter
Recalibrating the Plotter for Accuracy
RECONFIG.
7