Full menu mode
Default: 7586,
HP-GL/2

Device setup

Lang

7-7

Company confidential. Murillo/Ravillo User’s Guide. Final Freeze Status: Frozen

This is the cyan on page 7-7 (seq: 153)

This is the black on page 7-7 (seq: 153)

Changing the Graphics Language Setting for a
Different Application

Your software application communicates with the plotter by a graphics language.
The plotter supports HP industry standard CAD language

HP-GL/2 (7856)
HP-GL (7586B)
HP RTL

The plotter’s default setting is designed to work successfully with most
applications, and is called 7586, HP-GL/2. However, it’s possible that with some
older or less common applications, you may need to change this setting to
HP-GL/2, as explained in the table below.

To Change the Graphics Language Setting

Graphics
Language

Comments

7586, HP-GL/2

This should work successfully for most software applications.

With this graphics language setting another parameter is
available: Terminator. Try changing this setting from Normal
(the default) to Special:

D

if you are using an obsolete HP 7586 (pen plotter) driver,
and your plots are incomplete.

HP-GL/2

Try this setting:

D

if you have experienced plot position problems.

D

if you have experienced timing problems.

However, if you choose this setting, you don’t have access to
the Terminator option.

Reconfiguring Your Plotter

Changing the Graphics Language Setting for a Different Application

RECONFIG.