4 pppoe intermediate-agent access-node-id, 5 pppoe intermediate-agent circuit-id, Pppoe intermediate – PLANET XGS3-24042 User Manual
Page 1042: Agent access, Node, Agent circuit
57-3
57.4 pppoe intermediate-agent access-node-id
Command:
pppoe intermediate-agent access-node-id
no pppoe intermediate-agent access-node-id
Function:
Configure access-node-id field value of circuit ID in the added vendor tag.
Parameter:
Command Mode:
Global mode
Default:
access-node-id as MAC address of the switch
Usage Guide:
Use this configuration to create access-node-id of circuit ID in vendor tag. circuit-id value is
access-node-id +” eth “+ Slot ID + delimiter + Port Index + delimiter + Vlan ID, access-node-id
occupies n bytes (n<48), “ eth “ is space + e + t + h + space, occupy 5 bytes, Slot ID occupies 2
bytes, Port Index occupies 3 bytes, Vlan ID occupies 4 bytes, delimiter occupies 1 byte. In default
state, access-node-id value of circuit-id is switch’s MAC, it occupies 6 bytes. For example: MAC
address is “0a0b0c0d0e0f”, Slot ID is 12, Port Index is 34, Vlan ID is 567, the default circuit-id value
is “0a0b0c0d0e0f eth 12/034:0567”.
Example:
Configure access-node-id value of circuit ID as abcd in vendor tag.
Switch(config)#pppoe intermediate-agent access-node-id abcd
After port ethernet1/0/3 of vlan3 receives PPPoE packet, circuit-id value of the added vendor tag
as ”abcd eth
01/003:0003”.
57.5 pppoe intermediate-agent circuit-id
Command:
pppoe intermediate-agent circuit-id
no pppoe intermediate-agent circuit-id
Function:
Configure circuit ID of the port, the no command cancels this configuration.
Parameter:
Command Mode: