Reattaching the Protective Covers
Pass power wiring and control signal wiring through the exit holes on the bottom of the conduit bracket of the drive. Place
power wiring and control signal wiring in separate conduits. Properly connect all wiring after installing the drive and connecting
other devices. Reattach all protective covers when wiring is complete.
A
A –Pass power wiring and control signal wiring through different exit holes at the
bottom of the drive.
Figure 3.9 Reattach the Protective Covers and Conduit Bracket on an IP20/NEMA Type 1 Drive
u
IP20/NEMA Type 1 Top Cover Removal and Installation
To improve the ambient temperature rating of a NEMA Type 1 drive from 40 °C to 50 °C or to mount NEMA Type 1 drives
side-by-side, the top cover can be removed. Remove the top cover and set L8-35 to 2.
Note:
Removing the top cover of a NEMA Type 1 drive converts the drive to an IP20/Open-Chassis rating, and the drive will no longer have a
NEMA Type 1 rating.
n
Removing the Top Cover
Insert the blade of a straight-edge screwdriver into the opening of the top cover. Gently lift up on the front cover as indicated
by the arrow in
Figure 3.10 Removing the Top Cover
n
Reattaching the Top Cover
Align the connection tabs on the underside of the top cover with the connection tabs on the drive. Pinch in on the top cover
to click the cover into place on the drive.
Connection tabs
Figure 3.11 Reattaching the Top Cover
3.3 Protective Covers