Three-phase 200 v class drives – Yaskawa iQpump Micro User Manual
Page 219
u
Three-Phase 200 V Class Drives
Table A.2 Three-Phase 200 V Class Power Ratings
Item
Specification
Three-Phase Drive Model
2V0006
2V0010
2V0012
2V0020
Maximum Motor Size Allowed kW (HP)
<1>
1.1 (1.5)
2.2 (3)
3.0 (3)
5.5 (5)
Input
Input Current (A)
<2>
7.3
10.8
13.9
24.0
Output
Rated Output Capacity (kVA)
<3>
2.3
3.7
4.6
7.5
Output Current (A)
6.0
9.6
12.0
19.6
Overload Tolerance
120% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable 2 to 15 kHz
Max Output Voltage (V)
Three-phase power: 200 to 240 V
(proportional to input voltage)
Max Output Frequency (Hz)
400 Hz (user-adjustable)
Power Supply
Rated Voltage
Rated Frequency
Three-phase power: 200 to 240 V 50/60 Hz
DC power supply: 270 to 340 V
<4>
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency
Fluctuation
±5%
Harmonic Corrective
Actions
DC Link Choke
Optional
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor rated current.
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 230 V.
<4> DC is not available for UL standards.
Table A.3 Three-Phase 200 V Class Power Ratings Continued
Item
Specification
Three-Phase Model
2V0030
2V0040
2V0056
2V0069
Maximum Motor Size Allowed kW (HP)
<1>
7.5 (10)
11 (10)
15 (20)
18.5 (25)
Input
Input Current (A)
<2>
37.0
52.0
68.0
80.0
Output
Rated Output Capacity (kVA)
<3>
11.4
15.2
21.3
26.3
Output Current (A)
30.0
40.0
56.0
69.0
Overload Tolerance
120% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable 2 to 15 kHz
Max Output Voltage (V)
Three-phase power: 200 to 240 V
(proportional to input voltage)
Max Output Frequency (Hz)
400 Hz (user-adjustable)
Power Supply
Rated Voltage
Rated Frequency
Three-phase power: 200 to 240 V 50/60 Hz
DC power supply: 270 to 340 V
<4>
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency
Fluctuation
±5%
Harmonic Corrective
Actions
DC Link Choke
Optional
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor rated current.
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 230 V.
<4> DC is not available for UL standards.
A.1 Power Ratings
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
219
A
Specifications