No.

Description

Unit

Setting Range

Model

4V0011

4V0018

4V0023

4V0031

4V0038

o2-04

Drive Model Selection

97

99

9A

9C

9D

E2-11

Motor Rated Power

kW

5.5

7.5

11.0

15.0

18.5

b3-06

Speed Search current 1

0.5

0.5

0.5

0.5

0.5

b3-08

Current Control Gain during Speed Search

(Speed Estimation Type)

0.5

0.5

0.5

0.5

0.5

C6-02

Carrier frequency

7

7

7

7

7

E2-01

Motor rated current

A

9.8

13.30

19.9

26.5

32.9

E2-02

Motor rated slip

Hz

1.5

1.3

1.70

1.60

1.67

E2-03

Motor no-load current

A

2.6

4.0

5.6

7.6

7.8

E2-05

Motor line-to-line resistance

Ω

1.595

1.152

0.922

0.550

0.403

E2-06

Motor leakage inductance

%

18.2

15.5

19.6

17.2

20.1

E2-10

Motor Iron Loss

W

193

263

385

440

508

L2-02

Momentary power loss ride-through time

s

0.5

0.8

1

2

2

L2-03

Momentary power loss Baseblock time

s

0.7

0.8

0.9

1.0

1.0

L2-04

Momentary power loss voltage recovery time

s

0.3

0.3

0.3

0.6

0.6

L2-05

Uv detection voltage

V dc

380

380

380

380

380

L3-24

Motor acceleration time

s

0.154

0.175

0.265

0.244

0.317

L8-02

Overheat alarm level

°C

100

110

110

110

110

L8-09

Ground fault selection

0

1

1

1

1

L8-38

Carrier frequency reduction selection

1

2

2

2

2

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

B.16 Defaults by Drive Model