Refer to factory recommended branch circuit, For proper input fuse or circuit breaker sizing – Yaskawa iQpump Micro User Manual
Page 295

Drive
Model
Terminal
Recomm.
Gauge
AWG, kcmil
Wire Range
AWG, kcmil
Screw
Size
Tightening
Torque
N•m (lb.in.)
4V0018
R/L1, S/L2, T/L3
10
14 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
10
14 to 6
⊖, ⊕1, ⊕2
–
14 to 6
B1, B2
–
14 to 10
8
14 to 6
M5
2 to 2.5
(17.7 to 22.1)
4V0023
R/L1, S/L2, T/L3
10
10 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
10
10 to 6
⊖, ⊕1, ⊕2
–
10 to 6
B1, B2
–
14 to 10
8
10 to 6
M5
2 to 2.5
(17.7 to 22.1)
4V0031
R/L1, S/L2, T/L3
8
10 to 6
M5
3.6 to 4.0
(31.8 to 35.4)
U/T1, V/T2, W/T3
8
10 to 6
⊖, ⊕1, ⊕2
–
10 to 6
B1, B2
–
14 to 10
2.7 to 3.0
(23.9 to 26.6)
6
10 to 6
M6
5.4 to 6.0
(47.8 to 53.1)
4V0038
R/L1, S/L2, T/L3
6
10 to 6
M5
3.6 to 4.0
(31.8 to 35.4)
U/T1, V/T2, W/T3
8
10 to 6
⊖, ⊕1, ⊕2
–
10 to 6
B1, B2
–
10 to 8
2.7 to 3.0
(23.9 to 26.6)
6
10 to 6
M6
5.4 to 6.0
(47.8 to 53.1)
n
Factory Recommended Branch Circuit Protection for UL Compliance
Yaskawa recommends installing one of the following types of branch circuit protection to maintain compliance with UL508C.
Semiconductor protective type fuses are preferred.
Branch circuit protection shall be provided by any of the following according to
• Non-time Delay Class J, T, or CC fuses.
• Time Delay Class J, T, CC, or RK5 fuses.
• Semiconductor fuses.
• Molded Case Circuit Breakers (MCCB).
Table C.5 Factory Recommended Drive Branch Circuit Protection
Drive Model
Non-time Delay
Fuse Rating (A)
<1>
Time Delay Fuses
Bussmann
Semiconductor
Fuse Part Number
(Fuse Ampere)
<4>
MCCB
<5>
Class J, T, or CC
Fuse Rating (A)
<2>
Class RK5
Fuse Rating (A)
<3>
Rating (A)
Minimum
Enclosure
Volume (in
3
)
200 V Class Single-Phase Drives
BV0006
40
20
30
FWH-80B (80)
30
1152
BV0010
40
35
45
FWH-100B (100)
50
1152
BV0012
50
40
50
FWH-125B (125)
60
1152
BV0018
80
60
70
FWH-175B (175)
80
1152
200 V Class Three-Phase Drives
2V0006
20
10
15
FWH-25A14F (25)
15
1152
2V0010
25
15
20
FWH-70B (70)
25
1152
2V0012
25
20
30
FWH-70B (70)
30
1152
2V0020
40
40
50
FWH-90B (90)
60
1152
2V0030
–
60
80
FWH-100B (100)
90
1152
C.1 UL Standards
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
295
C
Standards Compliance