beautypg.com

Yaskawa iQpump Micro User Manual

Page 186

background image

Digital Operator Display

Minor Fault Name

Low Water in Tank

(LWT)

Low Water in Tank

Cause

Possible Solution

The water level in the tank is too low.

Shown when P4-24 = 2 and when the digital

input has been active (closed for P4-21 = 0,

or open for P4-21 = 1) for the time set in

P4-22.

• Check pressure switch contact for correct operation.
• Check control wiring to drive terminal strip from pressure switch contact.
• Check to make sure that suction pressure is present by means of a separate measuring device.
• Raise the water level.

Digital Operator Display

Minor Fault Name

LT-1

Cooling Fan Maintenance Time
The cooling fan has reached its expected maintenance period and may need to be replaced.

Note:

An alarm output (H2-oo = 10) will only be triggered if both (H2-oo = 2F and H2-oo =

10) are set.

Cause

Possible Solution

The cooling fan has reached 90% of its

expected performance life.

Replace the cooling fan and set o4-03 to 0 to reset the Maintenance Monitor.

Digital Operator Display

Minor Fault Name

LT-2

Capacitor Maintenance Time
The main circuit and control circuit capacitors are nearing the end of their expected performance life.

Note:

An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F.

Cause

Possible Solution

The main circuit and control circuit

capacitors have reached 90% of their

expected performance lives.

Replace the drive.

Digital Operator Display

Minor Fault Name

LT-3

Soft Charge Bypass Relay Maintenance Time
The DC bus soft charge relay is nearing the end of its expected performance life.

Note:

An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F.

Cause

Possible Solution

The DC bus soft charge relay has reached

90% of expected performance life.

Replace the drive.

Digital Operator Display

Minor Fault Name

LT-4

IGBT Maintenance Time (50%)
IGBTs have reached 50% of their expected performance life.

Note:

An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F.

Cause

Possible Solution

IGBTs have reached 50% of their expected

performance life.

Check the load, carrier frequency, and output frequency.

Digital Operator Display

Minor Fault Name

NETSCAN

Waiting for Master

(NETSC)

NETSCAN

Drive is waiting for a message from the master.

Cause

Possible Solution

No message was received from the master

within the time set in P9-28.

• Increase the P9-26 setting to account for network latency.
• Verify that there is a drive on the network with parameter P1-01 set to 3 and P9-27 to 0.
• Check network connections and verify H5-01 and P9-25 settings for all drives on the network.

Digital Operator Display

Minor Fault Name

NMS

SetPoint Not Met

(NOTSP)

Not Maintaining Setpoint

The setpoint cannot be maintained and P1-17 is set to 1.

Cause

Possible Solution

5.3 Alarm Detection

186

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual

This manual is related to the following products: