beautypg.com

Temperature derating, Altitude derating, Output current derating due to ambient temperature – Yaskawa iQpump Micro User Manual

Page 225

background image

u

Temperature Derating

As the ambient temperature for the drive is increased above the drive specification the drive should be derated. Additionally

parameter L8-35 Installation Method Selection on page

225

should be set according to enclosure type and mounting method

as illustrated in

Figure A.1

.

n

Output Current Derating Due to Ambient Temperature

Set L8-12 and L8-35 according to the installation conditions when the ambient temperature is above the drive specification

or when drives are mounted side-by-side in a cabinet. The output current is derated as shown in

Figure A.1

.

No.

Name

Description

Range

Def.

L8-12

Ambient

Temperature Setting

Adjust the drive overload (oL2) protection level when the drive is installed

in an environment that exceeds its ambient temperature rating.

-10 to 50

40 °C

L8-35

Installation Method

Selection

0: IP20/IP00 Drive

1: Side-by-Side Mounting

2: NEMA Type 1 Drive

3: Finless Drive or External Heatsink Installation

0 to 3

Dep. on

o2-04

40

50

0%

30

o

35

50%

70%

80%

85%

100%

o

o

o

Drive

Rating

Ambient tem

p C

Parameter L8-12

Parameter L8-35 = 0 (IP20/IP00 Drive)

Parameter L8-35 = 2
(NEMA Type 1 Drive)

Parameter L8-35 = 1
(Side-by-side Mounting)

Parameter L8-35 = 3
(Finless Drive or External
Heatsink Installation)

-10

o

o

Figure A.1 Ambient Temperature and Installation Method Derating

u

Altitude Derating

The drive standard ratings are valid for an installation altitude up to 1000 m. If the altitude exceeds 1000 m, both the drive

input voltage and the rated output current must be derated for 1% per 100 m. The maximum altitude is 3000 m.

A.4 Drive Derating Data

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual

225

A

Specifications