Three-phase 400 v class – Yaskawa iQpump Micro User Manual
Page 294
Drive
Model
Terminal
Recomm.
Gauge
AWG, kcmil
Wire Range
AWG, kcmil
Screw
Size
Tightening
Torque
N•m (lb.in.)
2V0030
R/L1, S/L2, T/L3
8
10 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
8
10 to 6
⊖, ⊕1, ⊕2
–
10 to 6
B1, B2
–
14 to 10
8
10 to 6
M5
2 to 2.5
(17.7 to 22.1)
2V0040
R/L1, S/L2, T/L3
6
10 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
8
10 to 6
⊖, ⊕1, ⊕2
–
10 to 6
B1, B2
–
14 to 10
6
10 to 6
M5
2 to 2.5
(17.7 to 22.1)
2V0056
R/L1, S/L2, T/L3
4
6 to 4
M6
5.4 to 6.0
(47.8 to 53.1)
U/T1, V/T2, W/T3
4
6 to 4
⊖, ⊕1, ⊕2
–
6 to 4
B1, B2
–
10 to 6
M5
2.7 to 3.0
(23.9 to 26.6)
6
8 to 4
M6
5.4 to 6.0
(47.8 to 53.1)
2V0069
R/L1, S/L2, T/L3
3
8 to 2
M8
9.9 to 11
(87.6 to 97.4)
U/T1, V/T2, W/T3
3
8 to 2
⊖, ⊕1, ⊕2
–
8 to 2
B1, B2
–
8 to 6
M5
2.7 to 3.0
(23.9 to 26.6)
6
6 to 4
M6
5.4 to 6.0
(47.8 to 53.1)
n
Three-Phase 400 V Class
Table C.4 Wire Gauge and Torque Specifications
Drive
Model
Terminal
Recomm.
Gauge
AWG, kcmil
Wire Range
AWG, kcmil
Screw
Size
Tightening
Torque
N•m (lb.in.)
4V0002
4V0004
R/L1, S/L2, T/L3
14
14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
14
14 to 10
⊖, ⊕1, ⊕2
–
14 to 10
B1, B2
–
14 to 10
14
14 to 10
4V0005
4V0007
4V0009
R/L1, S/L2, T/L3
14
14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
14
14 to 10
⊖, ⊕1, ⊕2
–
14 to 10
B1, B2
–
14 to 10
10
14 to 10
4V0011
R/L1, S/L2, T/L3
12
14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
14
14 to 10
⊖, ⊕1, ⊕2
–
14 to 10
B1, B2
–
14 to 10
10
14 to 10
C.1 UL Standards
294
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual