beautypg.com

Defaults by drive model, B.16 defaults by drive model, O2-04 – Yaskawa iQpump Micro User Manual

Page 286

background image

B.16 Defaults by Drive Model

No.

Description

Unit

Default Settings

Model

BV0006

BV0010

BV0012

BV0018

o2-04

Drive Model Selection

Hex

33

34

35

37

E2-11

Motor Rated Power

kW

1.1

2.2

3.0

3.7

b3-06

Speed Search current 1

0.5

0.5

0.5

0.5

b3-08

Current Control Gain during Speed Search (Speed

Estimation Type)

0.5

0.5

0.5

0.5

C6-02

Carrier frequency

7

7

7

3

E2-01

Motor rated current

A

6.2

8.5

11.4

14.0

E2-02

Motor rated slip

Hz

2.6

2.9

2.7

2.73

E2-03

Motor no-load current

A

2.8

3

3.7

4.5

E2-05

Motor line-to-line resistance

Ω

1.997

1.601

1.034

0.771

E2-06

Motor leakage inductance

%

18.5

18.4

19

19.6

E2-10

Motor Iron Loss

W

53

77

91

112

L2-02

Momentary power loss ride-through time

s

0.2

0.3

0.5

1.0

L2-03

Momentary power loss Baseblock time

s

0.4

0.5

0.5

0.6

L2-04

Momentary power loss voltage recovery time

s

0.3

0.3

0.3

0.3

L2-05

Uv detection voltage

V dc

160

160

160

160

L3-24

Motor acceleration time

s

0.142

0.145

0.145

0.154

L8-02

Overheat alarm level

°C

105

100

95

100

L8-09

Ground fault selection

0

0

0

0

L8-38

Carrier frequency reduction selection

1

1

1

1

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

B.16 Defaults by Drive Model

286

YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual