beautypg.com

SMA Sunny Data Control V.4.2 User Manual

Page 25

background image

SMA

Technologie AG

Connecting the PC to a Communication Device

User Manual

SDC-TEN080642

Page 25

We recommend the following cable types for indoors:
SMA data cable: COMCAB-INxxx*
*available in the following lengths xxx = 100 m/200 m/500 m und 1000 m.
Lappkabel: UNITRONIC Li2YCY (TP) 2 x 2 x 0,22 mm

2

Helukabel: PAAR-TRONIC-Li-2YCY 2 x 2 x 0,22 mm

2

Jumper Functions

Termination
To increase the signal quality of the RS485 data bus, it must be terminated at both ends.
Each termination occurs with a 120 W resistor between the two data lines. Terminate
the last Sunny Boy Control / Plus by means of a jumper. The position of the jumper is
described in the user manual of the Sunny Boy Control / Plus.

Signal Biasing
To increase the signal quality of the RS485 data bus, a maximum of one bias can be
connected in the data bus. We recommend connecting the bias at the PC.

Pin Assignment of the Connection Cable

Sunny Boy Control

PC

Signal

Pin

Pin

Signal

Data +

3

Data +

Data-

8

Data-

GND

5

GND