Kalypso Machine Control Interfaces Installation Instructions
Section 3 — VTR Interface
Define Engine the Application will Use
15.
Click on
Main Menu
in the right menu bar to return to the Main menu,
click on
Engines
in the right menu bar (
).
Figure 70. Encore Engines Menu
16.
Click on
Add
on the lower left corner of the screen. You are prompted
for an IP address. Type the IP address of the Serial Engine you
configured earlier (the default Serial Engine IP address often used is
198.162.0.15) and then press
Enter
.
Note
This IP address must be the same as the Serial Engine’s. You can check the
front panel display of the Serial Engine for its configured IP address.
17.
A prompt will then appear asking for an engine name. Type in
VTR
Control 1
(same as the application name) and press
Enter
.
18.
For the Platform, select
Device Control Engine (RISC-OS)
.
19.
Select
All Areas