beautypg.com

H3C Technologies H3C S12500 Series Switches User Manual

Page 406

background image

390

[SwitchA-bgp] quit

4.

Configure IPv6 BGP on Switch C.

system-view

[SwitchC] bgp 200

[SwitchC-bgp] ipv6-family

[SwitchC-bgp-af-ipv6] peer 3000::1 as-number 200

[SwitchC-bgp-af-ipv6] peer 3000::1 bfd

[SwitchC-bgp-af-ipv6] peer 2000::1 as-number 200

[SwitchC-bgp-af-ipv6] quit

[SwitchC-bgp] quit

5.

Configure BFD parameters (you can use default BFD parameters instead):
# Configure Switch A.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 100

{

Configure the minimum interval for transmitting BFD control packets as 500 milliseconds.

[SwitchA-Vlan-interface100] bfd min-transmit-interval 500

{

Configure the minimum interval for receiving BFD control packets as 500 milliseconds.

[SwitchA-Vlan-interface100] bfd min-receive-interval 500

{

Configure the detect multiplier as 7.

[SwitchA-Vlan-interface100] bfd detect-multiplier 7

{

Configure the BFD authentication mode as plain-text authentication, and set the authentication
key to ibgpbfd.

[SwitchA-Vlan-interface100] bfd authentication-mode simple 1 ibgpbfd

[SwitchA-Vlan-interface100] quit

# Configure Switch C.

[SwitchC] bfd session init-mode active

[SwitchC] interface vlan-interface 101

{

Configure the minimum interval for transmitting BFD control packets as 500 milliseconds.

[SwitchC-Vlan-interface101] bfd min-transmit-interval 500

{

Configure the minimum interval for receiving BFD control packets as 500 milliseconds.

[SwitchC-Vlan-interface101] bfd min-receive-interval 500

{

Configure the detect multiplier as 7.

[SwitchC-Vlan-interface101] bfd detect-multiplier 7

{

Configure the BFD authentication mode as plain-text authentication, and set the authentication
key to ibgpbfd.

[SwitchC-Vlan-interface101] bfd authentication-mode simple 1 ibgpbfd

[SwitchC-Vlan-interface101] return

6.

Verify the configuration:
The following operations are made on Switch C. Operations on Switch A and Switch B are similar.
(Details not shown.)
# Display detailed BFD session information.

display bfd session verbose

Total session number: 1 Up session number: 1 Init mode: Active