[SwitchA] ospf

[SwitchA-ospf-1] area 0

[SwitchA-ospf-1-area-0.0.0.0] network 10.1.1.0 0.0.0.255

[SwitchA-ospf-1-area-0.0.0.0] network 192.168.0.0 0.0.0.255

[SwitchA-ospf-1-area-0.0.0.0] network 121.1.1.0 0.0.0.255

[SwitchA-ospf-1-area-0.0.0.0] quit

[SwitchA-ospf-1] quit

[SwitchA] interface vlan 11

[SwitchA-Vlan-interface11] ospf cost 2

[SwitchA-Vlan-interface11] quit

# Configure Switch B.

system-view

[SwitchB] ospf

[SwitchB-ospf-1] area 0

[SwitchB-ospf-1-area-0.0.0.0] network 192.168.0.0 0.0.0.255

[SwitchB-ospf-1-area-0.0.0.0] network 13.1.1.0 0.0.0.255

[SwitchB-ospf-1-area-0.0.0.0] network 120.1.1.0 0.0.0.255

[SwitchB-ospf-1-area-0.0.0.0] quit

[SwitchB-ospf-1] quit

[SwitchB] interface vlan-interface 13

[SwitchB-Vlan-interface13] ospf cost 2

[SwitchB-Vlan-interface13] quit

# Configure Switch C.

system-view

[SwitchC] ospf

[SwitchC-ospf-1] area 0

[SwitchC-ospf-1-area-0.0.0.0] network 10.1.1.0 0.0.0.255

[SwitchC-ospf-1-area-0.0.0.0] network 13.1.1.0 0.0.0.255

[SwitchC-ospf-1-area-0.0.0.0] quit

[SwitchC-ospf-1] quit

3.

Configure BFD:
# Enable BFD on Switch A and configure BFD parameters.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 10

[SwitchA-Vlan-interface10] ospf bfd enable

[SwitchA-Vlan-interface10] bfd min-transmit-interval 500

[SwitchA-Vlan-interface10] bfd min-receive-interval 500

[SwitchA-Vlan-interface10] bfd detect-multiplier 7

[SwitchA-Vlan-interface10] quit

[SwitchA] quit

# Enable BFD on Switch B and configure BFD parameters.

[SwitchB] bfd session init-mode active

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] ospf bfd enable

[SwitchB-Vlan-interface10] bfd min-transmit-interval 500

[SwitchB-Vlan-interface10] bfd min-receive-interval 500

[SwitchB-Vlan-interface10] bfd detect-multiplier 6