beautypg.com

H3C Technologies H3C S12500 Series Switches User Manual

Page 351

background image

335

[SwitchB] ipv6

[SwitchB] ospfv3

[SwitchB-ospfv3-1] router-id 2.2.2.2

[SwitchB-ospfv3-1] quit

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] ospfv3 1 area 0

[SwitchB-Vlan-interface10] quit

[SwitchB] interface vlan-interface 13

[SwitchB-Vlan-interface13] ospfv3 1 area 0

[SwitchB-Vlan-interface13] quit

# Configure Switch C, enable OSPFv3, and configure the router ID as 3.3.3.3.

system-view

[SwitchC] ipv6

[SwitchC] ospfv3

[SwitchC-ospfv3-1] router-id 3.3.3.3

[SwitchC-ospfv3-1] quit

[SwitchC] interface vlan-interface 11

[SwitchC-Vlan-interface11] ospfv3 1 area 0

[SwitchC-Vlan-interface11] quit

[SwitchC] interface vlan-interface 13

[SwitchC-Vlan-interface13] ospfv3 1 area 0

[SwitchC-Vlan-interface13] quit

3.

Configure BFD:
# Enable BFD on Switch A and configure BFD parameters.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 10

[SwitchA-Vlan-interface10] ospfv3 bfd enable

[SwitchA-Vlan-interface10] bfd min-transmit-interval 500

[SwitchA-Vlan-interface10] bfd min-receive-interval 500

[SwitchA-Vlan-interface10] bfd detect-multiplier 7

[SwitchA-Vlan-interface10] return

# Enable BFD on Switch B and configure BFD parameters.

[SwitchB] bfd session init-mode active

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] ospfv3 bfd enable

[SwitchB-Vlan-interface10] bfd min-transmit-interval 500

[SwitchB-Vlan-interface10] bfd min-receive-interval 500

[SwitchB-Vlan-interface10] bfd detect-multiplier 6

4.

Verify the configuration:
The following operations are performed on Switch A. The operations on Switch B are similar.
(Details not shown.)
# Display the BFD information on Switch A.

display bfd session

Total Session Num: 1 Init Mode: Active

IPv6 Session Working Under Ctrl Mode: