Sundance SMT712 User Manual
Page 55

User Manual SMT712
Page 55 of 89
Last Edited: 11/12/2012 10:36:00
Clock Generator (AD9516-2) Register 0xAA – OUT9 Delay Full-scale – 0x130 (write)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Reserved
OUT9 Ramp Capacitors
OUT9 Ramp Current
Default
‘0’
‘0’
‘000’
‘000’
Clock Generator (AD9516-2) Register 0xAA – OUT9 Delay Full-scale – 0x130 (write)
Setting
Bit 5..3
Description (OUT9 Ramp Capacitors)
7
‘111’
1
6
‘110’
2
5
‘101’
2
4
‘100’
3
3
‘011’
2
2
‘010’
3
1
‘001’
3
0
‘000’
4
Setting
Bit 2..0
Description (OUT9 Ramp Current - uA)
7
‘111’
1600
6
‘110’
1400
5
‘101’
1200
4
‘100’
1000
3
‘011’
800
2
‘010’
600
1
‘001’
400
0
‘000’
200
4.6.1.1.34
Clock Generator (AD9516-2) Register 0xAB – OUT9 Delay
Fraction – 0x134 (write).
Clock Generator (AD9516-2) Register 0xAB – OUT9 Delay Fraction – 0x134 (write)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Reserved
OUT8 Delay Fraction
Default
‘0’
‘0’
‘000000’
Clock Generator (AD9516-2) Register 0xAB – OUT9 Delay Fraction – 0x134 (write)
Setting
Bit 5..0
Description (OUT9 Delay Fraction)
0
"000000" gives zero delay. Only delay values up to 47 decimals (101111b; 0x2F) are
supported.