Sundance SMT712 User Manual
Page 54

User Manual SMT712
Page 54 of 89
Last Edited: 11/12/2012 10:36:00
3
‘011’
2
2
‘010’
3
1
‘001’
3
0
‘000’
4
Setting
Bit 2..0
Description (OUT8 Ramp Current - uA)
7
‘111’
1600
6
‘110’
1400
5
‘101’
1200
4
‘100’
1000
3
‘011’
800
2
‘010’
600
1
‘001’
400
0
‘000’
200
4.6.1.1.31
Clock Generator (AD9516-2) Register 0xA8 – OUT8 Delay
Fraction – 0x128 (write).
Clock Generator (AD9516-2) Register 0xA8 – OUT8 Delay Fraction – 0x128
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Reserved
OUT8 Delay Fraction
Default
‘0’
‘0’
‘000000’
Clock Generator (AD9516-2) Register 0xA8 – OUT8 Delay Fraction – 0x128
Setting
Bit 5..0
Description (OUT8 Delay Fraction)
0
"000000" gives zero delay. Only delay values up to 47 decimals (101111b; 0x2F) are
supported.
4.6.1.1.32
Clock Generator (AD9516-2) Register 0xA9 – OUT9 Delay
Bypass – 0x12C (write).
Clock Generator (AD9516-2) Register 0xA9 – Out9 Delay Bypass – 0x12C (write)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
OUT8
Delay
Bypass
Default
‘0000000’
‘1’
Clock Generator (AD9516-2) Register 0xA9 – Out9 Delay Bypass – 0x12C (write)
Setting
Bit 0
Description (OUT9 Delay Bypass)
0
0
use delay function.
1
1
bypass delay function.
4.6.1.1.33
Clock Generator (AD9516-2) Register 0xAA – OUT9 Delay
Full-scale – 0x130 (write).