beautypg.com

Verifying the grounding, Submodule installation and grounding, Installation of protective isolator sheet – Gasboy FuelOmat system 8 Popt Commverter User Manual

Page 98: Connector mechanical outline – check procedure, Submodule - grounding, Submodule installation – wiring label placing, Sub-module, Installation, Grounding, Protective isolator sheet

background image

4.4.5.

Verifying the Grounding

Proceed as follows:

5. After connecting the Earth cable between the 8-port Commverter and the FCC

enclosure earth bar, use a multi-meter to verify its is properly grounded

6. Verify impedance [up to 5 Ω] between the 8-port Commverter chassis and the FCC

earth.

4.5.

SUB-MODULE INSTALLATION AND GROUNDING

NOTE

When installing piggy-backs on the CommVerter, power
to the board should disconnected

4.5.1.

Installation of Protective Isolator Sheet

Before installing a sub-module on the CommVerter main board, insert a Protective Isolator Sheet
(P/N 815608200) between the board and the sub-module. This Isolator Sheet prevents damage
during removal of the item from the board due to the use of a screwdriver or other unsuitable sharp
device.

4.5.2. Connector Mechanical Outline – Check Procedure

When installing a sub-module on the CommVerter main board, carefully check that the sub-module
connector mechanical outline is identical with the connector in the Main board. The current
connectors have a rectangular form, where in previous versions of the main board, the connectors
were circular. Do not use force, you may damage the boards!!!

4.5.3.

Sub-Module - Grounding

Once you have installed any sub-module (piggy-back board) on the main board, secure the sub-
module by locking it with the appropriate screw. This screw also serves as protective grounding.

4.5.4. Sub-Module Installation – Wiring Label Placing

In enclosed type CommVerter, after placing a piggy-back board on the PCB, stick the supplied
wiring label associated with the specific installed piggy-back. The label should be placed on the
rear panel, under the relevant piggy-back connector.

8 Port CommVerter Operation and Installation Manual

94