beautypg.com

Final procedures, Figure a-3 application setting parameters – Gasboy FuelOmat system 8 Popt Commverter User Manual

Page 124

background image

FINAL PROCEDURES

Proceed as follows:

 After checking that the correct parameters are displayed, click on “OK” button

 Close the application.

 Connect the CommVerter to switch hub anew

 Turn the CommVerter on

 Run the tfdp32.exe file and open the “tftpd32” application again (see Figure A-3)

 from your laptop, try to ping the CommVerter and confirm the valid communication

link

 Browse the CommVerter > admin task

 “Reset” the CommVerter. Reset also can be done by turning off then on the

CommVerter while the “tfdp32” application is open

 The firmware version is automatically updated within the CommVerter with the

“bsp8p_controler.bin” file (see Figure A-3). The upload process is shown
graphically.

Figure A-3 Application Setting Parameters

8 Port CommVerter Operation and Installation Manual

120