8 Port CommVerter Operation and Installation Manual

84

N

N

O

O

T

T

E

E

In cases where unit's IP is unknown or there is no
Ping to the unit, proceed as follows:
1. Turn OFF the unit
2. Short CN8 jumper pins 4 and 6 (see Figure 3-5)
3. Turn the unit back ON
4. Browse to the default IP address 192.168.1.108 to
view the current settings

1. Power OFF the unit

2. Short jumper CN8 pins 2 and 3

3. Power ON the unit

4. Connect the CommVerter to a PC (LAN Connection)

5. Open the Web browser, and enter the IP address of the

Commverter. The Setup Main Screen is displayed (see Figure
3-6)

Figure 3-6. CommVerter Unit Setup Site – Main Screen

6. Click on Admin Tasks. The Admin screen is

displayed. Scroll down the page to reach the
TCP/IP timeouts section (see Figure 3-7)