Counters description, Counters, Description – Gasboy FuelOmat system 8 Popt Commverter User Manual
Page 117

5.9.2.
Counters Description
This paragraph provides a description of the several counters, as shown in the Reset Counters list,
within the System Monitor screen.
Total System Reset – Holds the total resets occurred on system. Both unexpected resets (such as
power fail, manual reset and application crash), and application reset as when the application
experiences some critical fault (low memory, no communication and so) and must restart.
Total Application Reset – Holds all application reset as when the application experiences some
critical fault (low memory, no communication and so) and must restart. The total application reset is
equal to the sum of all types of reset as listed on the Web page.
Bad Initialized Value – Provides indication of some bad values on some global variables. This can
occur due to an unexpected crash prior to the reset.
Memory Allocation Fail – Indicates that the system has no memory.
Initialize Fail – Error that occurs during the application start-up.
One or more threads not responding – Provides indication that one or more active
communication threads is busy or not responding within the requested timeout (2 seconds). Means
the application has not reset the alive flag.
No Communication timeout for all channels – Indicate that no communication (both send &
receive) occurs on all active communication threads within the requested timeout.
User request for system reset – User request for manually reset from the Administrator Web page.
Low memory – The application identifies low when the heap memory is behind the minimum size
required by the application.
Low scan time - The application identifies that the main thread is too busy and not responding
within the expected time frame.
Data overlap fail – Provides indication about critical application problem while some data
variables overlap and have bad values.
8 Port CommVerter Operation and Installation Manual
113