Mechanical, Environmental, Protection – Gasboy FuelOmat system 8 Popt Commverter User Manual

Page 20: Mechanical 1.5.5. environmental 1.6. protection

background image

4 to 10 VDC (require wiring changes)

4

Pulsar Input High level sink
current (@15V)

3mA

5

Maximum pulse rate of
MPI-C at 50% duty cycle

Up to 5 KHz

6

In use "On" level (Input)

4 to 7 VDC

7

In use "Off" level (Input)

-1 to 1 VDC

8

In use Input impedance

10 KOhm

9

In use-max Input current
using external dry contact
(5VDC)

106 uA

10

In use-max Input current at 7
VDC

50 uA

11

12 VDC Output

25 mA max

1.5.4.

Mechanical

No.

Parameter

Value

1

Dimensions (HxWxD)

140 x 180 x 50 (mm)

1.5.5.

Environmental

No.

Parameter

Value

1 Operating

Temperature

-30

C to +55C

2

Operating Temperature (with power
supply)

-20

C to +50C

3

Storage Temperature

-30

C to +70C

1.6.

PROTECTION

The CommVerter in its 485 communication port (refer to Table 1-1) is protected electrically against
lightening and surges using transorbers and gas discharge (Arrosto) devices.

Additionally, grounding is required. Proper grounding is essential for protection to take place.

Refer to paragraph 4.4 - Grounding the Commverter.

8 Port CommVerter operation and installation manual