beautypg.com

Nuovo pignone connector pinout, Coptron communication to nuovo pignone card, Lan to rs232/485 application – Gasboy FuelOmat system 8 Popt Commverter User Manual

Page 65: Rs232/485, Application

background image

2.11.1. Nuovo Pignone Connector Pinout

The following pinout is required for the LAN to RS-232 application.

8 7 6 5 4 3 2 1

TX2- TX2+ RX2- RX2+ TX1- TX1+ RX1- RX1+

Channel 2

Channel 1

2.11.2. COPTRON Communication to Nuovo Pignone Card

Connector TB4A in Coptron pump (Pump Head 1

)

Table 2-2 . Pump Communication Connector for 8 Port NP Module

Coptron

Pin Out

Nuovo Pignone Card Pin Out

pin1_TXB pin3_Tx1+

pin2_ TXA

pin4_Tx1-

pin3_ RXB

pin1_Rx1+

pin4_ RXA

pin2_Rx1-

When Coptron dispenser detects serial-communication, it starts working in automatic mode.

2.12. LAN TO RS232/485 APPLICATION

This module is dual-purpose and supports two different communication protocols: RS232 and
RS485.

The LAN to RS-232 application is required when the connection to specific devices, such as TLGs,
is via RS-232. The RS232 circuit is dedicated for Channel 1

The LAN to RS-485 application is required when connecting fuel pumps and other serial devices to
home base controller that uses TCP/IP communication. The RS485 circuit is dedicated for
Channel 2.

NOTE

There is no external indication of the LEDs status.
Remove the Commverter cover to reveal the module
LEDs.

8 Port CommVerter Operation and Installation Manual

61