beautypg.com

Specifications, Communication rates, Electrical – Gasboy FuelOmat system 8 Popt Commverter User Manual

Page 19: Mechanical pump rates, Specifications 1.5.1. communication, Rates, Electrical 1.5.3. mechanical, Pump

background image

8 Port CommVerter operation and installation manual

15

1.5.

SPECIFICATIONS

Important Notice

At a rate above 9600 bps, the communication protocol with the 8Port Commverter shall handle 250 bytes
packets. The 8Port Commverter does not support a bytes stream flow at a rate higher than 9600 bps.

1.5.1.

Communication Rates

The communication rates depend on the type of module.

No.

Module

Value

1

RS-232 Module

57600 bps max.

2

RS-485 Module

57600 bps max.

3

TCP/IP Module

100 Mbps (optional)

4

Current Loop 24V 45mA

9600 bps max.

5

Tokheim

9600 bps max.

1.5.2.

Electrical

No.

Parameter

Value

1

Supply Voltage:

-

Enclosed

Commverter

unit

- PCB unit

110 – 230 VAC, 50-60Hz

15 to 24 VDC

2

Power Consumption

Typical 5W
Maximum 25W

3

Protection

1.5A Fuse, internal on board.

1.5.3.

Mechanical Pump Rates

No.

Parameter

Value

1

Power supply output voltage
to Pulsar Unit

12 VDC +/-20%

2

Power supply maximum
output current

80 mA max

3

Pulsar Input High level
voltage

10 to 16 VDC (standard)