beautypg.com

Mpi-c - dynamic pulser sampling period, General, Calculation – Gasboy FuelOmat system 8 Popt Commverter User Manual

Page 125: 2*pps) pw

background image

After the upload procedure is finalized, turn off the application.

 For the next upgrade, just change the firmware in the directory and perform the

above mentioned procedures.

NOTE

After each upload, try to configure the MAC address of
the CommVerter as well as other parameters as required.

MPI-C - DYNAMIC PULSER SAMPLING PERIOD

1.

GENERAL

The dynamic sampling period is introduced to better cope with low quality pulsers. The MPI-C is
required to count high frequency pulses ( up to 5K PPS ). With slower and low quality pulsers,
intermittent noise (resulting from pulser relay bouncing) is inside the band width of the 5K MPI-C
pulses range. It is suggested to have an adjustable pulser sampling period that will be closer to the
actual pulse rate.

2.

CALCULATION

The actual sampling rate will be calculated base on the Pulser Factor.

Parameters:

F = Factor in Pulse/Liter

FR = Pump Flow Rate in Liter/Min

PPS = Pulse per second

PW = Pulse Width in millisecond

Pulse

Liter

1

Pulse

F

Liter

* FR

Min

*

60

= PPS

Second

The pulse width for 50% duty cycle is

msec

= 1000

/

(2*PPS)

PW

8 Port CommVerter Operation and Installation Manual

121