Appendix b planning and connection of pi’s, General, Connectors – Gasboy FuelOmat system 8 Popt Commverter User Manual
Page 127: Working with commverter, General connectors working with commverter

0
APPENDIX B
PLANNING AND CONNECTION OF PI’S
GENERAL
This appendix provides the general rules with planning and connecting PI’s and tag readers/printers
to the LAN 8 port CommVerter.
Regarding PI type RS-485 interfaces, only the same brand pumps can be connected to either
channel. In case that any channel is left unused, Tag reader/printer can be connected to that port.
The Number of CPU heads connected to each PI has been optimized (see table in
paragraph 2.3).
All PI’s have protection against lightening/ESD
CONNECTORS
All the PI’s will be provided with relevant 8 pin connectors, each 4 pin shall represent a distinctive
channel.
WORKING WITH COMMVERTER
The CommVerter in all products supplied by Gasboy includes 4 slots for plug in units:
Slot 1 & 2 – Used for pump connection plug-in’s.
Slot 3 – Optional RS-232 plug-in for TLG (or other peripherals or electronic RS232 pump)
Slot 4 – Optional RS-485 plug-in for peripherals or electronic pumps (eg. Gasboy 485
pump).
The products are supplied by Orpak with the following plug-ins installed:
Any controller that support 2 mechanical pumps – One MPI-C plug-in in slot 1.
Any controller that support 4 mechanical pumps – One MPI-C plug-in in slot 1 and
One MPI-C plug-in in slot 2.
Any controller that support electronic pumps – One RS-485 plug-in in slot 1.
8 Port CommVerter Operation and Installation Manual
123